XR40XR40User’s Guide
6How your System OperatesYour system has been programmed to operate in one of threemodes: Area Arming, All/Perimeter, or Home/Sleep/Away.• Area Arming
7Area System ArmingArea Assignment: Your security system has been programmedinto separate areas. The number of areas and their names are listedin the
8Arming and DisarmingArea System DisarmingDisarming: While the system is armed, you can only enter thepremises through an exit/entry delay door withou
9All/Perimeter System ArmingArea Assignment: Your security system is divided into two separateareas. Motion detectors, inside doors, and other interio
10Arming and DisarmingAll/Perimeter System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay d
11Home/Away System ArmingArea Assignment: Your security system is divided into two or threeseparate areas. Motion detectors, inside doors, and other i
12Home/Away System DisarmingDisarming: While the system is armed, you can only enter thepremises through an entry/exit delay door without causing an a
13Security Command User MenuMany of the features of your system have been put into a User Menuyou can access from any Security Command keypad. The men
14User MenuZone Activity CheckUser Code Level: Master, Standard, Limited, or Scheduled.Your security system may be programmed for the Zone ActivityChe
15User MenuSensor ResetUser Code Level: Master, Standard, Limited, or Scheduled.Function: Resets smoke or glassbreak detectors. Also clears Fireand Su
Copyright © 1999 - 2000 Digital Monitoring Products, Inc.Information furnished by DMP is believed to be accurate and reliable.This information is subj
16Zone MonitorUser Code Level: Master, Standard, or Limited.Function: Allows the system to monitor selected disarmed zones(doors, windows, or motion
17User MenuSystem TestUser Code Level: Master, Standard, or Limited.Function: System Test is used to test the battery, alarm bell or siren,and commun
18User Code Authority LevelsAdding User codes:1. Access the User Menu.2. Press the COMMAND key until USER CODES? displays.3. Press any SELECT key. The
1910. After you've completed making your selections, the keypaddisplay shows USER # ADDED.11. Press the ARROW key once to add another user or twi
20User MenuUser Codes continued5. At the USER NUMBER: - prompt, enter the user number tochange and press COMMAND.6. The display changes to CODE NO
21Extended SchedulesUser Code Level: Master or Standard.Function: This option allows users to extend today's programmedclosing time schedule.Ext
22Output SchedulesUser Code Level: MasterSetting Output (OUT) schedulesThe Schedules function allows you to set up a schedule for each ofthe four out
23User MenuTime and DateUser Code Level: Master only.Function: Allows you to change the current date and time displayedon the keypad and used by the
24Zone Activity Check Event DisplayThis displays the date and time the Zone Activity Check was enabledor disabled.16-Character Display DescriptionACT
25User MenuArming and Disarming Event DisplaysThis displays any arming or disarming of system areas.16-Character Display DescriptionARM 3 12 10
Security CommandSecurity Command®® User's Guide User's Guide for XR40 Command ProcessorTM PanelsTable of ContentsiAbout your SystemEmergency
26User MenuSystem Monitor Event DisplaysThis displays any loss of the system's AC power or battery.16-Character Display DescriptionPOWER TBL 10
27Service Request?User Code Level: Master onlyFunction: Allows you to send a Request for Service message to thecentral station when there is a problem
28System SetupSystem SetupWe've provided this System Setup section to allow you to track thecurrent status of the programmable options on your Se
29System SetupHOW TO FILL IN THISTABLE# - The User Number of theperson authorized to use thesystem.Level - Standard, Master,Limited, or Scheduled auth
30The relay activates forfive seconds duringwhich you must open thedoor.Once you open the door,you have 30 seconds toexit and close the doorbefore th
31AppendixARMING AND DISARMING AN ALL/PERIMETER SYSTEMPress Command. The keypad displays PERIM ALL (when arming) or DISARM?.Press the Select key unde
32Pager Direct™Security Command Alphanumeric PagingArea NamesSecurity Command Numeric PagingArea NamesPager Direct™ User's GuidePager Direct uses
33AppendixSecurity Command Numeric PagingThis number has been programmed into your Security Command systemas an identifier. Whenever the system sends
34AppendixFA113 User's GuideThese instructions guide you through the operation of the XR40 Command Processor system using the FA113 Wireless Keyc
35PhoneAccess™ User's GuideThis exciting feature allows you to call your XR40 system from any outside touchtone phone to arm and disarm protectio
Emergency Evacuation PlansThe National Fire Protection Association recommends that youestablish an emergency evacuation plan to safeguard lives in the
361. Call the panel phone number. The panel answers and sounds oneshort tone.2. Enter your code within 8 seconds. One beep means the code is good.Four
37Alarm displayshow long in display 5Ambush codes 20area restrictions 20arming only 20ArmingAll/Perimeter mode 9Area mode 7Home/Away mode 11Instant mo
38LT-0494 (10/00)
1About Your Security SystemYour Security Command system has been designed with yoursafety and comfort in mind. It uses the latest in computer technolo
2Data Entry keysThese keys allow you to enter your user code when arming ordisarming or enter other information into the system.The ARROW keyThe ARROW
3Special Security Command TonesYour keypad also contains a small speaker that allows it to alert youto events as they occur on your system. Below are
4Understanding Security System TermsThroughout this guide, and in some displays on your keypad, you’llsee certain words or phrases that might be unfam
5Understanding Security System TermsCentral Station MonitoringYour system can also be programmed to automatically send alarm,trouble, and arming and d
Commenti su questo manuale